Test Code LYTESPROF Electrolyte Panel (Na, K, CL, CO2)
Specimen Requirements
Panel includes: Sodium, Chloride, Potassium, CO2, Anion Gap
Container/Tube: GRN/SST
Preferred: Plasma
Acceptable: Serum
Specimen Volume: 1.0 mL
SPECIMEN PROCESSING and HANDLING
Complete clot formation should take place before centrifugation. Serum or plasma should be physically separated from cells as soon as possible with a maximum limit of two hours from the time of collection.
TRANSPORT TEMPERATURE
Sodium in serum and plasma are stable for at least one week either at room or refrigerator (2 – 8 °C) temperature and for at least one year frozen.
PERFORMING LAB
WKMC, WKB, WKP, WKS