Test Code HGBA1C Hemoglobin A1c (Adv. HbA1c NGSP)

Important Note

HbA1c values of 5.7-6.4 % indicate an increased risk for developing diabetes mellitus. HbA1c values greater than or equal to 6.5 % are diagnostic of diabetes mellitus. Willis Knighton Laboratory has adopted the ADA's recommendation to use a new term in diabetes management, Estimated Average Glucose, or eAG. This will allow healthcare providers to report A1C results to patients using the same units (mg/dL) that patients see routinely in blood glucose measurements.

HgbA1c % Estimated Average Glucose (eAG) mg/dL

6.0 126

6.5 140

7.0 154

7.5 169

8.0 183

8.5 197

9.0 212

9.5 226

10.0 240

10.5 255

11.0 269

11.5 283

12.0 298

SOURCE: American Diabetes Association: https://professional.diabetes.org/glucose_calc Formula: eAG = {(HgbA1C x 28.7) - 46.7}

Infectious

Additional Codes

MEDITECH MNEMONIC:

HGBA1C

Specimen Requirements

Preferred Specimen:

3mL EDTA Whole Blood

 

Minimum Volume:

2mL EDTA Whole Blood (does not include repeat or reflex testing)

 

Setup Schedule:

SUN-SAT

 

Reject:  Non-EDTA whole blood, clotted, or low volume specimens

Transport Temperature/Stability

Transport Container:

Original tube (EDTA)

 

Preferred Transport Temperature:

Ambient up to 8 hours

 

Specimen Stability:

Ambient:  8 hours

Refrigerated:  7 days

Frozen:  >1 month

Performing Laboratory

Willis Knighton Medical Center

Willis Knighton Bossier

Willis Knighton Pierremont