Test Code FCMVQ CMV by PCR
Reporting Name
CMV Quant PCRAmniotic Fluid
Performing Laboratory
University of Colorado Hospital Clinical LaboratorySpecimen Type
Amniotic FldSpecimen Required
1 mL amniotic fluid shipped frozen.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Amniotic Fld | Frozen | 180 days |
Reference Values
Note Detected = No virus detected.
Detected - Virus detected.
<1000 IU/mL = Virus detected below the minimum quantitative range.
1000 IU/mL to 1,000,000 IU/mL = Virus detected within quantitative range.
>1,000,000 IU/mL = Virus detected above maximum quantitative range.
This test employs real-time PCR amplification of a Cytomegalovirus-specific conserved genetic target.  A positive result should be coupled with clinical indicators for diagnosis. A "Not detected" result for this assay does not exclude Cytomegalovirus involvement in a disease process.
Day(s) Performed
Monday through Friday
Test Classification
This test was developed and its performance characteristics determined by the UCH Clinical Laboratory. It has not been cleared or approved by the U.S. Food and Drug Administration. The FDA has determined that such clearance or approval is not necessary. This test is used for clinical purposes. It should not be regarded as investigational or for research. This laboratory is certified under the Clinical Laboratory Improvement Amendment of 1988 ("CLIA") as qualified to perform hig complexity clinical testing.CPT Code Information
87497
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
FCMVQ | CMV Quant PCR | 34720-3 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
Z0161 | CMV Quant PCR | 34720-3 |
Report Available
3 to 6 daysReject Due To
Other | Non sterile or leaking containers; Sample not properly identified; Insufficient sample volume and Contaminated specimen |
Method Name
DNA amplification by Polymerase chain reaction (PCR) using a CMV-specific DNA probe detected by real-time PCR.